Advisory (ICSA-14-226-01)

Siemens SIMATIC S7-1500 CPU Denial of Service

Original release date: August 14, 2014

Legal Notice

All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/.


Arnaud Ebalard from Agence Nationale de la Sécurité des Systèmes d’Information (ANSSI) has reported a denial-of-service (DoS) vulnerability in Siemens SIMATIC S7-1500 CPU. Siemens produced a new firmware version that mitigates this vulnerability and then reported it to NCCIC/ICS-CERT.

This vulnerability could be exploited remotely.


The following Siemens SIMATIC S7-1500 CPU versions are affected:

  • SIMATIC S7-1500 CPU all versions before V1.6


A successful exploit of this vulnerability will cause the CPU to automatically restart and remain in the “STOP” mode. The CPU would then need to be manually put into the “RUN” mode to restore operations.

Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.


Siemens is a multinational company headquartered in Munich, Germany.

Products in the Siemens SIMATIC S7-1500 PLC family have been designed for discrete and continuous control in industrial environments such as manufacturing, food and beverages, and chemical industries worldwide.




Specially crafted TCP packets could cause a DoS of the device if sent in a specific order.

CVE-2014-5074b has been assigned to this vulnerability. A CVSS v2 base score of 7.1 has been assigned; the CVSS vector string is AV:N/AC:M/Au:N/C:N/I:N/A:C.c



This vulnerability could be exploited remotely.


No known public exploits specifically target this vulnerability.


An attacker with a moderate skill would be able to exploit this vulnerability.


The firmware update for S7-1500 V1.6 can be obtained at the following location on the Siemens web site:


Siemens recommends running the affected software components in a protected network environment and to configure the environment according to operational guidelines.d

For more information regarding this issue (SSA-310688) or any other security issue involving Siemens products, please see the Siemens ProductCERT security advisory page at:


ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at: http://ics-cert.us-cert.gov/content/recommended-practices. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site (http://ics-cert.us-cert.gov/).

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.

Contact Information

For any questions related to this report, please contact ICS-CERT at:

Email: ics-cert@hq.dhs.gov
Toll Free: 1-877-776-7585
International Callers: (208) 526-0900

For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov