IOServer Out of Bounds Read Vulnerability

Original release date: April 10, 2014 | Last revised: September 06, 2018

Legal Notice

All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/.



OVERVIEW

Chris Sistrunk of Mandiant and Adam Crain of Automatak have identified an out of bounds read vulnerability in IOServer’s OPC Server application. IOServer has released a new version that mitigates this vulnerability. The researchers have tested the new version to validate that it resolves the vulnerability.

This vulnerability could be exploited remotely.

AFFECTED PRODUCTS

The following IOServer versions are affected:

  • OPC Drivers Versions 1.0.20 and prior.

IMPACT

An attacker who exploits this out of bounds read vulnerability may be able to crash the OPC Server application software running on the target system.

Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.

BACKGROUND

IOServer is an Australian company based in Sydney, Australia.

The affected product, OPC Server, is a Windows-based (WindowsNT/95/98/ME/
2000/2003/XP/2008/7) OPC Server that allows OPC clients, such as human-machine interface and supervisory control and data acquisition systems, to exchange plant floor data with programmable logic controllers. According to IOServer, the affected product is deployed across multiple sectors including Commercial Facilities, Critical Manufacturing, Energy, and Water and Wastewaster Systems.

VULNERABILITY CHARACTERIZATION

VULNERABILITY OVERVIEW

OUT OF BOUNDS READa

The Modbus slave/outstation driver for IOServer’s OPC Server application may be forced to read outside of the intended memory register. By sending a specially crafted packet, an attacker could crash the software. This could significantly interrupt process control.

CVE-2014-0777b has been assigned to this vulnerability. A CVSS v2 base score of 8.3 has been assigned; the CVSS vector string is (AV:N/AC:M/Au:N/C:P/I:P/A:C).c

VULNERABILITY DETAILS

EXPLOITABILITY

This vulnerability could be exploited remotely.

EXISTENCE OF EXPLOIT

No known public exploits specifically target this vulnerability.

DIFFICULTY

An attacker with a moderate skill would be able to exploit this vulnerability.

MITIGATION

IOServer has produced a new version that mitigates the vulnerability. The new version, Beta2112.exe, is available for download here:

http://www.ioserver.com/

ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.

ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at: http://ics-cert.us-cert.gov/content/recommended-practices. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01B—Targeted Cyber Intrusion Mitigation Strategies, that is available for download from the ICS-CERT web site (http://ics-cert.us-cert.gov/).

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.


Contact Information

For any questions related to this report, please contact the NCCIC at:

Email: NCCICCUSTOMERSERVICE@hq.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  http://ics-cert.us-cert.gov 
or incident reporting:  https://ics-cert.us-cert.gov/Report-Incident?

The NCCIC continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

Was this document helpful?  Yes  |  Somewhat  |  No

Back to Top